1-800-A E R O F I N

Login Vertical Aeromix Coil Plate Fin Type W Coil Transformer Oil Cooler Nuclear, Safety Related Coil

Home
Products
Offices
Literature
Quick-Ship
Sales Inquiries
Contact Us
History
Employment  
Code of Ethics
PRC Manufacturing License
ASME & NBCA
ISO
SIRA


Software Updates

Rep/OEM
Standard Version Download

 


w.JPG (12739 bytes) Aerofin® Type W
Standard 5/8" OD tube coil for heating and cooling
Type W coils are the standard plate fin water coils, used for both heating and cooling applications. A typical latent and sensible cooling load requires from 4 to 12 rows of aluminum or copper plate fin surface. Standard construction includes threaded connections on carbon steel or non-ferrous supply and return headers. This coil type falls within the scope of ARI standard 410 Certified Ratings.

wd.JPG (12413 bytes) Aerofin® Type WD
Standard 5/8" OD tube coil with intermediate drain headers for heating and cooling
Similar to type W coils, type WD coils feature intermediate drain headers located on the rows between the supply and return headers. The intermediate drain headers enhance drainability and help coils drain more quickly and thoroughly. Coils are meant to be installed pitched towards the header end. This coil type falls within the scope of ARI standard 410 Certified Ratings.

wr.JPG (11349 bytes) Aerofin® Type WR
Cleanable 5/8" OD tube coil with dual removable headers for heating and cooling

Type WR coils differ from type W coils in that removable headers are supplied instead of manifolds. This design allows access to the internal tubes for inspection and cleaning from either end of the coil. The headers are baffled to direct the fluid flow for numerous circuiting options, with vents and drains provided in the individual compartments. This coil type falls within the scope of ARI standard 410 Certified Ratings.


Top of page

wrc.JPG (12045 bytes) Aerofin® Type WRC
Cleanable 5/8" OD tube coil with a single removable header for heating and cooling
Similar to type WR coils, type WRC coils have a removable header only on the piping connection end. The opposite end has return bends, making the type WRC coil very useful in applications where access is limited. This coil type falls within the scope of ARI standard 410 Certified Ratings.  

hw.JPG (13594 bytes) Aerofin® Type HW
Standard 5/8" OD tube coil for heating and cooling
Type HW coils are designed for use with hot water, glycols, or steam and are available in 1 or 2 row configurations. Standard construction includes threaded connections on carbon steel or non-ferrous supply and return headers. This coil type falls within the scope of ARI standard 410 Certified Ratings.

hwp.JPG (9674 bytes) Aerofin® Type HWP
5/8” OD tube duct booster coil for heating
Type HWP duct booster coils are for use with hot water or steam, available in 1 or 2 row configurations. Threaded female connections are provided at the inlet and outlet tube locations in lieu of manifold headers. This coil type falls within the scope of ARI standard 410 Certified Ratings.

Top of page

hd.JPG (13153 bytes) Aerofin® Type HD
 5/8” OD tube non-freeze steam coil for heating
Type HD steam coils are designed for freezing air, heating applications. The non-freeze design is accomplished with inner-distributing tubes (tube within a tube construction). Outer finned tubes are 5/8” OD. Tubes are pitched for horizontal air flow. For vertical air flow, coil must be installed pitched towards the header end for positive condensate drainage. Type HD coils are available with 1 or 2 rows and are typically used for applications with low to moderate steam condensate loads. This coil type falls within the scope of ARI standard 410 Certified Ratings.

hm.JPG (12937 bytes) Aerofin® Type HM
1” OD tube non-freeze steam coil for heating
Similar to HD coils, type HM steam coils use 1” OD finned outer tubes. It features tube within a tube construction, and tubes are pitched for horizontal airflow. For vertical airflow, coil must be installed pitched towards the header end for positive condensate drainage. Type HM coils are only available with 1 row and are used for applications with high steam condensate loads. This coil type falls within the scope of ARI standard 410 Certified Ratings.

Top of page


  Note to users of the Aerofin coil selection program; the latest revision is 3.5.4. 

Home · History · Products · Offices

© 2010 Aerofin. All Rights Reserved.
Equal Opportunity Employer
Please click
HERE to send comments about this site.